Rice Lake RL50210 TA, 50-500 lb. Capacities Mild Steel User Manual

Page 7

Advertising
background image

7

6. Repeat Steps 4, 5, and 6 for the remaining mounts. The vessel should now be

supported on the mounts alone.

7. If necessary, move the vessel to its final position. Verify that there is no initial

misalignment between the base plate and top plate by lifting the vessel
slightly at each support point in turn. This will also indicate if the load is
evenly distributed on all mounts. Shim if necessary.

8. Attach the base plates to the foundation using anchors for concrete or by

bolting or welding to a steel structure. Verify that the base plates are no more
than

±

0.5

°

out of level. Shim as necessary.

9. Check that the top plates are no more than

±

0.5

°

out of level. Shim if necessary

and fully tighten the bolts.

10. The load distribution can be checked more accurately by exciting each load

cell and measuring the output with a voltmeter. The variation in load among
the cells should be no more than 20%. Shim if necessary.

11. Check that the two screws securing the load cell to the base plate are tight. The

torque values are listed in the following table.

)