2 profibus led status indicators and connector – Rice Lake 880 Performance Series Panel Mount Indicator/Controller - Profibus DP Interface Option Installation and Programming Manual User Manual

Page 11

Advertising
background image

Installation

7

2.2

Profibus LED Status Indicators and Connector

An LED array on the

Profibus

module provides status information for

troubleshooting.

LED 1 provides network status;

LED 2 provides status indication for the

Profibus

module.

Figure 2-10. Profibus Status LED Module

Operation Mode LED (Item 1)

Module Status LED (Item 2)

Status

Description

Off

No powered or not online

Steady Green

Data exchange

Flashing Green

Clear

Flashing Red (1-flash)

Parametrization error

Flashing Red (2-flash)

Profibus configuration error

Status

Description

Comments

Off

Not initialized

Anybus state = ‘SETUP¨’ or ‘NW_INIT’

Steady Green

Initialized

Anybus module has left the ‘NW_INIT’ state

Flashing Green

Initialized, diagnostic
event(s) present

Extended diagnostic bit is set

Steady Red

Exception error

Anybus state = ‘EXCEPTION’