12

920i Based Truck In/Out Weigh Program

2.10 Diagnostics

Figure 2-17 shows an example of a 920i display of iQube diagnostic information. Information shown includes the
following:

• Cell name
• Cell deadload value (mV)
• Current individual cell and total values (mV)
• Number of weighments
• Cell status for highlighted cell. Use the indicator navigation keys to select cells.

Displayed deadload and current values are raw millivolt values. All diagnostic measurements use corrected mV
values:

corrected_value = current_value – deadload_value

Figure 2-17. 920i Diagnostic Display

The 920i diagnostic display can be shown by pressing the

Diagnostic

softkey (if configured).

In setup mode, diagnostic information can be shown by going to the VERS menu, pressing the

Contact

softkey,

then the

Next

softkey.

Access through the VERS menu also displays softkeys for

Clear Diagnostics

and, if cell emulation is enabled,

Cell

Emulation

. If cell emulation is set to AUTO2 or MANUAL2, a

Snapshot

softkey is also shown.

Note

10/22/07

08:05AM

SCALE #1

Diagnostics

NAME

DEADLOAD

0.1871
1.1509
0.7567
0.3791
0.0931
0.7079

CURRENT

0.2159
0.0547
0.7301
0.3583
0.1565
0.6655

A2-Load Cell 2
A3-Load Cell 3
A4-Load Cell 4
A5-Load Cell 5
A6-Load Cell 6
A7-Load Cell 7

System 1
44 weighments over 1000 grads

17.24608

Cell OK

Previous

Done

Cell

Emulation

Next

Advertising