10 diagnostics – Rice Lake 920i Based Truck In/Out System User Manual
Page 16
12
920i Based Truck In/Out Weigh Program
2.10 Diagnostics
Figure 2-17 shows an example of a 920i display of iQube diagnostic information. Information shown includes the
following:
• Cell name
• Cell deadload value (mV)
• Current individual cell and total values (mV)
• Number of weighments
• Cell status for highlighted cell. Use the indicator navigation keys to select cells.
Displayed deadload and current values are raw millivolt values. All diagnostic measurements use corrected mV
values:
corrected_value = current_value – deadload_value
Figure 2-17. 920i Diagnostic Display
The 920i diagnostic display can be shown by pressing the
Diagnostic
softkey (if configured).
In setup mode, diagnostic information can be shown by going to the VERS menu, pressing the
Contact
softkey,
then the
Next
softkey.
Access through the VERS menu also displays softkeys for
Clear Diagnostics
and, if cell emulation is enabled,
Cell
Emulation
. If cell emulation is set to AUTO2 or MANUAL2, a
Snapshot
softkey is also shown.
Note
10/22/07
08:05AM
SCALE #1
Diagnostics
NAME
DEADLOAD
0.1871
1.1509
0.7567
0.3791
0.0931
0.7079
CURRENT
0.2159
0.0547
0.7301
0.3583
0.1565
0.6655
A2-Load Cell 2
A3-Load Cell 3
A4-Load Cell 4
A5-Load Cell 5
A6-Load Cell 6
A7-Load Cell 7
System 1
44 weighments over 1000 grads
17.24608
Cell OK
Previous
Done
Cell
Emulation
Next