PL9710 Installation Manual

4. The last number of the weight display will be

flashing, telling you that number is ready to be
changed. To change the number’s value, press the

Up

or

Down

key. To select a different number,

press the

left arrow

or

right arrow

softkey.

5. When the number on the weight display matches

your trailer’s (channel 1) loaded weight, press the

Enter

softkey to store the weight in the indicator’s

memory.
The information display will show Store Ch-1 full
weight
then return to Setup selection. And the
weight display will show Setup.

6. To enter the trailer’s loaded weight, press the

Up

or

Down

key until the information display shows

Calibrate Channel 2.

7. Press the

Full

softkey. The information display

will briefly show Load Channel 2 before
Entering Full weight
. It will then show Enter
Ch-2 Full Weight
.

8. The last number of the weight display will be

flashing, telling you that number is ready to be
changed. To change the number’s value, press the

Up

or

Down

key. To select a different number,

press the

left arrow

or

right arrow

softkey.

9. When the number on the weight display matches

your trailer’s (channel 2) loaded weight, press the

Enter

softkey to store the weight in the indicator’s

memory.
The information display will show Store Ch-2 full
weight
then return to Setup selection.

At any time, you can exit the calibration process by
pressing the

Cancel

softkey.

T h e i n f o r m a t i o n d i s p l a y w i l l b r i e f l y s h o w
CANCEL-Setup.

3.3 Advanced Calibration

Another way to enter the loaded weight into the
indicator is with the advanced calibration feature. This
method allows the calibration of several trucks to be
centrally controlled. The driver does not have to enter
the setup mode of the indicator, even for calibration.
After setting in the tare weight, the driver need only
record two sets of numbers:

• The truck and trailer loaded weight shown by the

platform scale.

• The channel 1 and channel 2 weights recorded on

the

PL9710

while the truck is on the platform scale.

The following steps are used for the advanced
calibration, which can be done on an empty truck.

1. Press the

Menu

key for 5 seconds until the

information display shows Setup Menu.
After releasing the

Menu

key, the information

display will show Setup selection and the weight
display will show Setup.

2. Press the

Up

or

Down

key until the information

display shows Set Advanced calibration.

3. Select the channel to calibrate by pressing the

CH-1

softkey or the

CH-2

softkey.

For this example, we will assume you selected
CH-1.

4. Enter the number that was earlier recorded as the

number shown on the indicator’s weight display
for channel 1 while sitting on the platform scale.
Change the numbers in the same manner as then
setting the original loaded-weight calibration. See
“Entering the Loaded Weight” on page 5. Pres
s
the

Enter

softkey when completed.

5. The information display will show

Enter Ch. 1

Legal weight

.

6. Enter the number that was earlier recorded as the

legal truck weight from the platform scale.
Change the numbers in the same manner as in
Step 4, above.

7. Press the

Enter

softkey when completed.

The information display will show Advanced
calibration Ch. 1
and then show Setup selection.

8. Press the

Cancel

softkey to return to normal

operation.

Channel 2 is calibrated in a similar manner.