0 using the serial ports, 1 setting the serial ports, 2 connecting a serial printer – Rice Lake Combination System - Precision Loads PL9710 Indicator User Manual

Page 16: Using the serial ports, Setting the serial ports, Connecting a serial printer

Advertising
background image

12

PL9710 Installation Manual

6.0 Using the Serial Ports

The rear panel of the

PL9710

indicator has connectors to provide RS232 serial output for printers, remote displays,

remote keypads, an on-board computer, or other peripherals. Two communication ports are available, COM1 and
COM3. Both COM ports have the following specifications:

• Baud rates: 1200, 2400, 4800, and 9600 baud

• Parity: None

• Stop bit: 1

• Data: 8 bits

Only the baud rates are selectable. The default baud rate is 9600.

COM1 is used for output to a printer or to accept input from a bar-code scanner or external keypad.

COM3 is used for a large-digit remote readout (scoreboard) or a wireless remote handheld display.

6.1 Setting the Serial Ports

Two options are available when setting the serial ports,
the baud rate and whether or not continuous output is
needed. If you are using the PL6050 printer, do not
change the default of 9600 baud.

1. Press the

Menu

key for about 10 seconds until the

information display shows Setup Serial Port.

2. After releasing the

Menu

key, the information

display will show Setup selection and the weight
display will show Setup.

3. To set the COM1 baud rate, press the

Print

key

until the information display shows Select Baud
COM1.
If you need a baud rate other than the default
9600, press the appropriate softkey. The selected
baud rate will show at the end of the first line in
the display.

4. Press the

Cancel

softkey to complete the selection

and return to Setup selection.

5. To set the COM3 baud rate, press the

Up

key until

the information display shows Select Baud
COM3.
Select the proper baud rate.

6. To set up COM1 for continuous output, press the

Up

key until the information display shows

COM1 Send Continuous YES.
Press the appropriate softkey for YES or NO. The
selection will show at the end of the first line in
the display.

7. Press the

Cancel

key to complete the selection

and return to Setup selection.

8. To set up COM3 for continuous output, press the

Up

key until the information display shows

COM3 Send Continuous YES.

9. Press the

Cancel

softkey to complete the selection

and return to Setup selection.

10. Press the

Cancel

key again to return to normal

operation.

6.2 Connecting a Serial Printer

A serial printer has a two-wire cable, which connects to
the back of the

PL9710

indicator at the COM1 serial

port. The power wire attaches to the 12VDC positive
(+) terminal, the ground wire connects to the GND (-)
terminal, and the signal wire connects to the TXD
terminal. Consult the printer operator’s manual for the
ground and signal wire colors.

For the printer to operate properly, the COM1
baud rate must be set to 9600 baud (Step 3
above).

The COM1 serial port should not be set for continuous
output (Step 6 above) if
a printer is connected. Continuous
output will cause the printer to print a ticket each time the
indicator’s weight display is updated. With continuous
output set to NO, the printer will print a ticket only when
the PRINT key is pressed on the indicator’s front panel.

Figure 6-1. Serial Printer Connections