0 advanced setup, 1 enabling the filter, 2 selecting the number of load cells per channel – Rice Lake Combination System - Precision Loads PL9710 Indicator User Manual

Page 26: 3 enabling load/delivery, 4 enabling lift-to-weigh, Advanced setup, Enabling the filter, Selecting the number of load cells per channel, Enabling load/delivery, Enabling lift-to-weigh

Advertising
background image

22

PL9710 Installation Manual

12.0 Advanced Setup

The Advanced Setup menu includes sub-menus for:

• Enabling the filter
• Selecting the channel mode (1 or 2 channels)
• Setting the number of load cells connected to the

indicator

• Enabling the load/delivery (LD) feature for

incremental weighing

• Enabling the lift-to-weigh feature for tipping

operations

• Enabling the cal
• Enabling the accumulator to store up to 100

weighing events

The sections for the sub-menus in this chapter are written to be independent of each other. If you wish to use more

than one of the sub-menus, press the

Cancel

softkey only once at the end of the selection sequence. Then use the

Up

or

Down

key to select another sub-menu. Pressing the

Cancel

softkey twice will return the indicator to normal

operation.

12.1 Enabling the Filter

When the filter is enabled, the indicator will average 2,

4, or 8 data samples before displaying the weight.

Using the filter will stabilize the display (numbers will

not bounce around as much) but the display will be

slower to update.

1. Press the

Menu

key for about 12 seconds until the

information display shows Advanced Setup

Menu.
After releasing the

Menu

key, the information

display will show Setup selection and the weight

display will show Setup.

2. To select the Filter submenu, press the

Up

key

until the information display shows Filter: None.

3. Press the

More

softkey or

Less

softkey to decrease

filtering.

4. Press the

Cancel

softkey to return to the submenu

selection.

5. Press the

Cancel

softkey again to exit Advanced

setup and return to normal operation.

12.2 Selecting the Number of Load Cells

Per Channel

1. Press the

Menu

key for about 12 seconds until the

information display shows Advanced Setup

Menu.

2. After releasing the

Menu

key, the information

display will show Setup selection and the weight

display will show Setup.

3. To select the Number of Load Cells submenu,

press the

Up

key until the information display

shows Number of Load Cell Ch1=2.

4. Press the appropriate key to select the number of

load cells that are connected to Channel 1.

5. Press the

Cancel

softkey and then the

Up

key for

Channel 2.
The information display will show Number of

Load Cell Ch2=2

6. Repeat Step 4 to select the number of load cells

that are connected to Channel 2.

7. Press the

Cancel

softkey to return to the submenu

selection.

8. Press the

Cancel

softkey again to exit Advanced

Setup and return to normal operation.

12.3 Enabling Load/Delivery

1. Press the

Menu

key for about 12 seconds until the

information display shows Advanced Setup

Menu.

2. After releasing the

Menu

key, the information

display will show Setup selection and the weight

display will show Setup.

3. To select the Load/Delivery submenu, press the

Up

key until the information display shows

Enable Load/Delivery YES.

4. Press the appropriate softkey for

Yes

or

No

.

5. Press the

Cancel

softkey to return to the submenu

selection.

6. Press the

Cancel

softkey again to exit Advanced

Setup and return to normal operation.

12.4 Enabling Lift-to-Weigh

1. Press the

Menu

key for about 12 seconds until the

information display shows Advanced Setup

Menu.

2. After releasing the

Menu

key, the information

display will show Setup selection and the weight

display will show Setup.

3. To select the Lift to Weigh submenu, press the

Up

softkey until the information display shows

Enable Lift to Weigh: Yes.

4. Press the appropriate softkey for

Yes

or

No

.

5. Press the

Cancel

softkey to return to the submenu

selection.

6. Press the

Cancel

softkey again to exit Advanced

Setup and return to normal operation.

Advertising