Troubleshooting Guide

7

4.0

Troubleshooting Guide

Table 4-1. Benchmark Troubleshooting Table

Symptom

Probable Cause

Remedy

No display

Power disconnected

Connect power

Cable cut or disconnected

Repair cable

Signal leads incorrectly wired at indicator

Connect according to the manual

Display starts at zero

Incorrect load cell cable connections

Connect according to the manual

Faulty indicator

Service indicator

Erratic Weight display

Vibration near the scale

Remove the source of the vibration, or adjust
digital averaging of indicator to minimize erratic
display

Scale not level

Level the scale

Water damage to the load cell or cable

Replace the load cell

Faulty indicator

Service the indicator

Loose load cell screws

Tighten to correct torque

Faulty load cell

Test and replace if necessary

Consistently low weight

Indicator not properly adjusted to zero

Zero indicator correctly

Scale deck cover binding

Obtain adequate clearance

Overload stops set too high

Reset the stops correctly

Indicator not calibrated for scale

Calibrate the scale

Faulty load cell

Test and replace if necessary

Use the following troubleshooting tips for the Benchmark scale if necessary.