Rice Lake iQUBE2 Digital Diagnostic Junction Box - Transient Protection Kit User Manual

Transient protection kit installation, Iqube, Junction box

Advertising
background image

February 2014

160051

iQube

2

Junction Box

Transient Protection Kit Installation

Transient protection boards are recommended on each end of a power supply run when an external DC supply is
used, and on any power supply cables to secondary units where the secondary enclosure runs are longer than 75
feet. To replace a transient protection board (PN 101369) in the iQUBE

2

use the following instructions.

Note

For more information on the iQube

2

, see the Installation manual (PN 106113).

Manuals can be viewed or downloaded from the Rice Lake Weighing Systems website at

www.ricelake.com

.

Mounting Bracket

PN 107026

4-40NC x 1/4 screws

PN 14825

Transient Protection Board

109396

Figure 1. Transient Protection Kit

With AC/DC Power Installed

1. Disconnect the power to the iQUBE

2

.

2. Loosen the top screws and remove the cover from the iQUBE

2

.

3. Disconnect all cables attached to the power board.

4. Loosen screws to remove the power board assembly.

Remove CPU board
power cable

Remove AC Input
cable

Screws connecting power
assembly to enclosure

Figure 2. Remove Power Board Assembly

Note

Transient Protection Kit comes assembled to a mounting bracket, for installation in unit with AC power the
mounting bracket can be removed from the transient board and discarded. Transient protection board can be
mounted to the bottom of existing power supply mounting bracket.

The transient protection board can be installed in either direction, the connectors are crossed over to prevent a
connection error.

5. Align transient protection board assembly with the standoffs located on the bottom of the mounting bracket

6. Secure to bracket with four 4-40NC x 1/4 screws.

Advertising
This manual is related to the following products: