Existing Power
Supply Assembly

Standoffs

Transient
Protection Board

4-40NC x 1/4 screws

2

Transient Protection Kit Installation

Figure 3. Install Transient Protection Board to Power Supply Mounting Bracket

7. Reinstall power bracket assembly in the iQube

2

enclosure.

8. Connect Power cable to the power supply.
9. Strip and install a new two wire cable between the power supply and the transient board.
10. Use the power supply cable to connect the transient board to the CPU board (J6).

Power supply
cable

CPU Board (J6)

CPU Power
Supply Cable

Transient Board
J1

Transient Board
J2

New two wire
cable

Figure 3-1. Connect Cables

+ VDC

+ VDC

GND

GND

In from
power

Out to CPU
Board (J6)

Figure 3-2. Transient Protection Board Wiring

11. Replace the enclosure cover.
12. Reconnect power the iQube2.