Without ac/dc power installed – Rice Lake iQUBE2 Digital Diagnostic Junction Box - Transient Protection Kit User Manual

Page 3

Advertising
background image

Transient Protection Kit Installation

3

Without AC/DC Power Installed

1. Disconnect the power to the iQUBE

2

.

2. Loosen the top screws and remove the cover from the iQUBE

2

.

3. Disconnect power cable from CPU board (J6).

4. Install the transient protection assembly into the enclosure.

Transient Protection
Assembly

4-40NC x 1/4" screws

Power Cable

J6

Note

The transient protection board can be installed in either direction, the connectors are crossed over to prevent a
connection error.

Figure 4. Install Transient Protection Assembly

5. Connect existing power cable to the transient protection board (J2).
6. Connect a new two wire cable from the transient protection board (J1) to the CPU board (J6).

Power supply
cable

CPU Board (J6)

Transient Board
J1

Transient Board
J2

New two wire
cable

Figure 4-1. Connect Cables

+ VDC

+ VDC

GND

GND

In from
power

Out to CPU
Board (J6)

Figure 4-2. Transient Protection Board Wiring

7. Replace the enclosure cover.
8. Reconnect power the iQube2.

Advertising
This manual is related to the following products: