14

Error Messages

dISP

dISP

dISP

dISP

Display error, the scale is unable to display the number completely. If no
weight on the scale, press zero to return the weight reading to zero.

EEPE

EEPE

EEPE

EEPE

EEPROM error, the scale has had it's calibration corrupted or destroyed;
the scale will require calibration.

OE

OE

OE

OE

The scale is over capacity or outside the A/D converter range. Reduce the
load to the scale. If the CS200 continues to display “OE

OE

OE

OE”, the problem

could be a bad load cell, bad load cell wiring, or a bad chip on the circuit
board.

OvEr

OvEr

OvEr

OvEr

The CS200 is over capacity. Reduce the load on the pad.

BATT

BATT

BATT

BATT

Low battery, the unit requires a new battery. It will shut off if this message
is ignored for too long.


Changing the Battery

Turn the power off. Slide the battery hatch down. Next, remove the battery from the
case and unsnap the used battery. Snap in the new battery and replace the battery in
the case. Replace the cover.