Introduction, Specifications, Controls – Rice Lake Intercomp SWII™ Portable Vehicle Scale User Manual

Page 3: Electrical, Performance, Environmental

Advertising
background image

SWII Users

Rev I, May 2009

Page 3 of 11

Introduction


This manual contains specifications and operating instructions for Intercomp's SWII
Scale System.

Specifications

Controls

General:

On, Off, %/WGT, TEST/ZERO, Left Front, Right
Front, Left Rear, Right Rear

Channel selection:

Any combination

Display:

4 digit, LCD (0.5”)

Indicators:

Left Front, Right Front, Left Rear, Right Rear, Low
Battery, Selected %

Electrical

Voltage:

12 VAC/VDC, 120/240 VAC

Batteries:

6 x AA-size disposable alkaline cells or rechargeable Nickel-
Cadmium cells.

Battery Life:

6 - 8 hours on fully recharged Ni-Cad cells. 20-25 hours on
fresh alkaline cells.

Auto Off:

The system will automatically shut off after 1 hour without use
or motion.

Filtering:

Analog: Trans-besel filter
Digital: Average of several internal weights gives steady
readings for unstable loads
Auto-zero: Satisfies all HB-44 requirements

Input:

Input: 4 analog channels

Performance

Speed:

1 sec to typical reading (static)

Accuracy:

±

0.1% of applied load or

±

display graduation, whichever is greater

Divisions:

6000 lb/ 2800 kg capacity: graduation = 1 lb/0.5 kg
8800 lb/ 4000 kg capacity: graduation = 1 lb/0.5 kg

Environmental

Humidity:

10 to 95% non-condensing

Temperature:

Storage: -40

°

C to +75

°

C. / -40

°

F to +170

°

F

Operating -10

°

C to +40

°

C. / +14

°

F to +104

°

F