Contrast Control Potentiometer Installation

PN 160965

The following instructions are for the installation of the Contrast Control Potentiometer into the 920i Weighcenter.

Figure 1. Contrast Control Potentiometer Installed

1. Remove the screws to remove the front bezel from the weighcenter frame.

Figure 2. Remove Front Bezel

2. Drill a 25/64

” hole in the front bezel at 3/4” under the power switch.

A 3/8

bit will work if you ream the hole with the bit.

Figure 3. Drill Hole

Remove all screws

Note

Drill Hole

Power Switch