Contrast Control Potentiometer Installation

3. Insert the potentiometer into the hole and tighten down with 1/2

” wrench.

Ensure the white wire is oriented towards power switch as shown.

Figure 4. Install Contrast Control Potentiometer

4. To remove back plate, remove the screws securing the it to the indicator.

Figure 5. Remove Indicator Back Plate

5. Route the 8-pin connector cable through cord grip.

Figure 6. Route Wiring Through Cord Grip

Note

Power Switch

Contrast Control
Potentiometer

White wire towards
power switch

Remove all screws

Route Cable