4.2

Initial Setup of the OB-350 Indicator

The system password allows access modification of the options: Configuration, Calibration and System Setup
menus. When in the configuration and setup menus, the function keys will perform the following functions:

M

E

N
U

(OK)

Diagnostics
Alarms
Options

Configuration
Calibration
System

A

B

C

D

E

Figure 4-3. Setup Mode

A

Accept or Enter key - enters data

B

Down arrow key - scrolls down within the menu selection

C

Up arrow key - scrolls up within the menu selection

D

Carriage Return/Circle - Previous screen or back function
When in a menu function (password) and OK is not visible, use this key as the enter and accept.

E

Selectable MENU options

Options

Modes

Select weighing mode to be displayed - Net. Gross or Net & Gross. See Section 4.6.

Load/Chan

Load function gives the option to accumulate the amount of load (weight) delivered or
collected from site.

Channel Function - Split screen function is added to the MENU screen.

RS-232

Select or change RS-232 output option.

Count

Select count by in kg - 1, 2, 5, 10, 20, 50, 100, 200,

Z/Func

Allows operator access to Zero/Tare function on the display.

Inc

For use with roll off systems and dump trucks, turn on to calibrate zero degrees of
inclinometer.

Configuration

Input 1(F)
Input 2 (R)
Split
CAN

Air/Oil pressure transducer or load cell setting on truck type.
Air/Oil pressure transducer or load cell setting on truck type.
Setting varies depending on input 1/input 2 values.
Not Used

Calibration

Tare
Zero
Span

Entry of empty vehicle weight for gross weight calculation.
No load zero calibration.
Entry of load for span calibration.

System

Pin
PUK
Clock

Enter a password.
Not Used.
Change system time and date.

User and Setup Menu

Parameter

Choices

Description

Table 4-1. User and Setup Menu – Electrical Wiring and Data Connections

Advertising