Cabling

MSI provides a field installable mating connector (MSI
#13587) that allows customers to interface with their own
Ethernet cabling. The connector accepts cables up to 8mm.

Cable Assembly

1. First slide the pressure nut 1 and the housing 2 over

the cable (Fig.1).

2. Strip the cable sheath over a length of approx.

28mm. Trim the braided shield to a length of
approx. 12mm (Fig. 2).

3. See table 1 for the core assignment.
4. Guide the individual cores fully into the marked

chambers. Pay attention to use the correct
chambers and only

5. one core per chamber (Fig. 3).
6. Contact the cores by pressing the termination blocks

4 together according to Fig. 4 and Fig. 5. The
termination blocks engage at the end stop.

7. Pull the housing 2 out as far as the plug insert 3 and

hold it tight while you screw the plug insert onto it
(Fig. 6).

8. Push the pressure nut 1 on the housing. Tighten the

pressure nut firmly (Fig. 7).

Pin

TIA 568 B

Color

Function

1

White/Orange

TD+

2

Orange

TD-

3

White/Green

RD+

4

Green

RD-