0 configuration, Configuration – Rice Lake Prove Statistical Printer User Manual
Page 9
Configuration
5
3.0
Configuration
The Prove statistical printer incorporates a number of configurable options, each of
which has a number of settings. The default settings of the standard printer are
detailed in Table 3-1 in bold. To change the settings of any option, follow the
directions below.
1. Ensure power to the printer is off.
2. Press and hold the
Mode
button. In approximately five seconds the status light
(LED) will flash five times to show that the printer is in configuration mode.
Release the
Mode
button.
3. Press the
Power
button the same number of times as the option that you want to
change (for example, to change the baud rate, press the
Power
button twice).
4. After a short delay, the status light will flash the same number of times as the
option you have chosen. If you make a mistake at this stage, simply wait a
moment, and the printer will power on without changing any options.
5. To proceed with configuration, press the
Power
button the same number of
times as the setting you wish to make.
Option
Numbers
Description
Settings
Setting
Number
1
RS-232 Protocol
8, no parity
8, odd parity
8, even parity
7, odd parity
7, even parity
1
2
3
4
5
2
RS-232 Baud Rate
115200
57600
38400
19200
9600
4800
2400
1200
600
300
1
2
3
4
5
6
7
8
9
10
3
RS-232 Flow Control
None
Software
Hardware
1
2
3
4
Font
Arial 16, 24 CPL
Arial 12, 32 CPL
Arial 8, 48 CPL
1
2
3
5
Character Format
Normal
Double width
Double height
Double width and height
1
2
3
4