Rice Lake Mechanical Stationary Animal Scale - MAS-LM User Manual

Page 13

Advertising
background image

Shackle
Assembly

Nose irons

Steelyard
Rod

Assembly and Installation

9

Figure 2-7. Assembly Shackle

3. Place the shackle assembly between the nose irons of the pipe lever assembly.
4. Place the long threaded steelyard rod through the hole in the bottom of the weighcenter.
5. Screw the steelyard rod into the shackle assembly.

Load cell
assembly

Secure to
plate with
nuts

Load cell
assembly

Screw
steelyard rod
into load cell
assembly

Figure 2-8. Load Cell Assembly

6. Open the cover of the weighcenter and place the load cell assembly inside, secure to plate with nuts.
7. Screw the threaded steelyard rod into the bottom of the load cell assembly.
8. The load cell can be wired into the indicator.
9. Level the pipe lever arms by turning the threaded rod.
10. The scale can now be calibrated by a certified service provider.

Note

To remove the weighcenter reverse the above steps.

Advertising