1 display windows and annunciators, 2 error messages, 1 weight calibration – Rice Lake RS-130 - Operation Manual User Manual

Page 10

Advertising
background image

6

RS-130 Operation Manual

3.1

Display Windows and Annunciators

Table 3-2. Display Windows

Display Window

Description

WEIGHT

Displays the weight of the object on the platter.

UNIT PRICE $

Displays the unit price of the object on the platter.

TOTAL $

Displays the total amount owed (weight multiplied by unit price).

Indicates scale

is in NET mode

Indicates scale

is at ZERO

Indicates weight

is in either lb, kg,

or oz (oz not

available in

Canada)

Status of battery charging

Red: initial charge

Orange: charging

Green: fully charged

Indicates the

amount of cash

received

Indicates the

amount of change

due

Figure 3-1. Front Display Annunciators

3.2

Error Messages

Table 3-3. Error Messages and Troubleshooting

Display

Description

Corrective Action

WEIGHT

display shows

"Err-1"

IC93C66 data-loss or IC93C66 damaged/
faulty

Contact your nearest RLWS dealer

WEIGHT

display shows

"Err-3"

At power-up, the weight on the platter is
more than 5% of the maximum capacity

Remove the weight from the scale, or to under 5%
of capacity and restart the scale

TOTAL $

display shows

"E"

The total price value is larger than 9999.99

Remove the measured object from the platter and
press CLEAR to clear the unit price setting

Table 3-3 describes error messages that may be shown on the RS-130 display.

0 - 9 Numeric

Keys

Enter the numeric value required.
• Use the numeric keys to enter the price-per-unit, PLU number, cash received
Press and hold the 0 key to show the battery voltage in the

WEIGHT

display.

6.1

-

6.5

means the battery is fully-charged.

• Less than

5.6

means the battery is in low-charge.

• Press the

CLEAR

key to return the display to normal operating mode.

Key

Function/Description

Table 3-1. Function Keys

Advertising