RS-130 Retail Scale Calibration Instruction Sheet

3

2.0

RS-130 Retail Scale Calibration Instruction Sheet

Warning

Procedures described require work inside the scale enclosure. These procedures are to be
performed by qualified service personnel only.

2.1

Weight Calibration

Follow the steps below to complete the calibration process.

1. Turn on power and press and hold the

CHANGE

key until the WEIGHT display shows

6.3

and UNIT

PRICE $ display shows

-3-

. Release the

CHANGE

key

2. Press and hold the

ZERO

key until the WEIGHT display shows

SEtUP

.

3. Press the

ZERO

key to enter calibration mode. WEIGHT display flashes

CAL-1

and shows

UNIT 1

.

Note

The WEIGHT display will not flash CAL-1 if jumper JP1 is in the disable position. See “Setting JP1 to the
Enable/Disable Position” on page 2. if the WEIGHT display will not flash CAL-1.

4. Press the

CLEAR

key to select the weight unit (default is kg) to be used for calibration.

Unit 1 - kg (annunciator above kg lit in the UNIT PRICE $ display)

Unit 2 - lb (annunciator above lb lit in the UNIT PRICE $ display)

Unit 3 - oz (annunciator above oz lit in the UNIT PRICE $ display) - not available in Canada

5. Press the

CHANGE

key to accept the weight unit. The WEIGHT display shows:

00.000 (kg)

000.00 (lb)

0000.0 (oz) - not available in Canada

6. Press the

key to shift and the

CLEAR

key to modify the flashing digit. For example, If you use a 30lb

standard weight to calibrate; use the

key to shift the flashing digit to

000.00

and use the

CLEAR

key to

set the digit to

030.00

.

7. Press the

CHANGE

key and wait for the

WEIGHT

display to show

000000

and the UNIT PRICE $ display to

show the internal offset value at (

xxxxx

.)

8. Place selected weight from step six on the platter.

WEIGHT

display shows the internal span value and

UNIT PRICE $ display shows the internal offset value at (

xxxxx

.)

9. Wait for the span value to become stable, then press the

CHANGE

key. Wait for the

WEIGHT

display to

flash

good

(twice), quickly remove the weight from the platter. After automatic restart, finish calibration.

10. Disable JP1 to maintain the NTEP approval. See “Setting JP1 to the Enable/Disable position”.

2.2

Setting JP1 to the Enable/Disable Position

Follow the steps below to set jumper JP1 to the enable or disable position.

1. Remove platter and plastic in-use cover.
2. Remove lead-seal located in the center of the base.
3. Remove the 4 screws from the base of the scale.
4. Lift the cover away from the base toward the operator side.

Note

Open slowly, cables are attached.

Advertising