Installation

3

Load Cell Wiring

To attach the load cell cable to the connector board,
plug the cable into external connector (see Figure 2-6
on page 6).

Wire load cell cables as shown in Table 2-1.

2.5

Serial Communications

The J4, J6 and J7 serial communications ports on the

iQube

connector board support communications

between the

iQube

and a host device (PC and/or

remote display.)

Port J4 supports full-duplex RS-232
communications between the

iQube

unit and a

host device.

Port J6 and J7 are used to connect to the
remote display(s).

To attach serial communications cables, plug cable
into the external DB-9 connectors labeled Remote
Display.

Table 2-2 shows the pin assignments for connectors
J4, J6, and J7.

Communications Cable Distance Limitations

The maximum cable lengths that can be used for
various communications types depend on a number of
factors. These include: output impedance of the
transmitter; electrical noise in the environment; cable
capacitance, gauge, termination, and shielding.

Given that these and other factors will affect the
maximum usable cable length, the following distances
c a n b e u s e d a s a g e n e r a l g u i d e f o r

i Q u b e

communications cabling (10 ft cable is provided):

RS-232:

50 ft (15 m)

2.6

Core Module DIP Switches

The DIP switches on the

iQube

core module must be

set to configure the

iQube

as a primary or secondary

unit, and to specify the type of serial communications
provided by the unit. Table 2-3 lists the DIP switches
and their functions.

2.7

Core Module Reset Procedure

If

VIRTUi

does not recognize the connection to the

load cell, the core module may need to be reset to
initialize the

iQube

firmware.

To reload the default firmware into the

iQube

core

module, do the following:

1. Power-off the

iQube

. Remotely powered units

can be powered off by temporarily removing
fuse F1 (see Figure 2-1 on page 2).

2. Set core module DIP switch 8 ON.

3. Power-on the

iQube

.

4. Power-off the

iQube

.

5. Set DIP switch 8 OFF.

6.

Power-on the

iQube

. The reset is now complete.

DB-9 Pin

Female Connector

On-Board

Connector

(J3)

Function

7

1

+SIG

3

2

–SIG

4

3

+EXC

6

4

–EXC

5

5

SHIELD

Table 2-1. Load Cell Connector Pin Assignments

Connector

DB-9 Pin

Pin

Signal

J4

(Host Com)

Male 2

1

TxD

Male 3

2

RxD

Male 5

3

Gnd

J6

(Remote)

Female 1

1

DC+

Female 2

2

GnD

Female 9

3

TxD

J7

(Remote)

Female 1

1

DC+

Female 2

2

GnD

Female 9

3

TxD

Table 2-2. Serial Port Pin Assignments

Switch

Function

Values

1–3

Primary

OFF, OFF, OFF = PRIMARY

4

Setup enable

ON = setup enabled

5

Host
communication
protocol

OFF = RS-232

6

Host
communication
port

OFF = Port J7

7

Reserved

OFF

8

Load default

OFF

Table 2-3. Core Module DIP Switch Settings