PC Configuration

11

Zero Scale

1. In gross mode, remove all weight from the

scale and wait for the standstill annunciator.

2. Press the Zero key. The Center of Zero

annunciator lights to indicate the scale is
zeroed.

Acquire Tare

1. Place container on scale and wait for standstill

annunciator.

2. Press the TARE key to acquire the tare weight

of the container. The indicator switches to net
mode.

Remove Stored Tare Value

1. Remove all weight from the scale and wait for

the standstill annunciator.

2. Press the TARE key. The indicator switches to

gross mode, indicating the tare value has been
removed.

Print Ticket

1. Wait for standstill annunciator.

2. Press the Print key to send data to the serial

port.

3.1.5

Web Browser-Based Cell Status

iQube

load cell status can be reported via a standard web browser. A “http://localhost:5050” URL is used to view

the status page. “Http” must be included as it is not inferred, and “localhost” can be replaced with the appropriate
IP address or domain name.

Figure 3-9. Cell Status

3.1.6

System Requirements

Minimum

Windows 98 or greater

Internet Explorer 5.5 or greater

.NET Framework 1.1

64 MB RAM

30 MB free hard drive space

Serial port connection for connection to

iQube

Additional serial ports are required for connection to
printers/remote displays.

Recommended

Windows 2000 or greater

Internet Explorer 6.0 SP1

.Net Framework 1.1

128 MB RAM

30 MB free hard drive space

Serial port for connection to

iQube

Additional serial ports are required for connection to
printers/remote displays.