0 specifications, Specifications, Power – Rice Lake Tracer AVi - v2.0 User Manual

Page 21: A/d specifications, Serial communications, Environmental, Weight, Enclosure, Certifications and approvals, Specifications 17

Advertising
background image

Specifications

17

6.0

Specifications

Power

Auto-Ranging Input 100-240 VAC, 50-60 Hz

1-channel, 350

Ω load cell

75 mA (0.563 W)

A/D Specifications

Excitation Voltage

4 VDC (+4V and ground, single-sided)

Analog Signal Input Range

–11.7 mV to +27.3 mV

A/D Sample Rate

15 Hz

Serial Communications

J4 Port

Full duplex RS-232

J6 Port

Simplex RS-232

J7 Port

Simplex RS-232

Environmental

Operating Temperature –10 to +40°C (14 to 104°F)
Storage Temperature

–10 to +70°C (14 to 158°F)

Humidity

0–95% relative humidity

Weight

1.5 lbs

Enclosure

Enclosure Dimensions 4.9” W x 3.0” H

Certifications and Approvals

NTEP
CoC Number

03-032

Accuracy Class

III/IIIL