Smart Power Systems LR Series User Manual

Page 23

Advertising
background image

Smart Power

®

Systems

A. C. MODULAR GENERATOR SYSTEM

Page 22 of 49

Enabling System Purge Option

The purge option can also be set by performing the following steps:

Step 3: Hold Mode
until Amps Line 1
Blinks 88. Release
switch so 0Pt

appears.

Step 4: Press mode to
make PvrG

appear.

Step 5: Press On/Off
until

y

appears.

Figure 10


1. If the Command & Control Center is dark, press the Mode switch to put

the display into Normal mode.

2. If the Display looks like Figure 11, The purge option is enabled.
3. Otherwise, press and hold the Mode switch until the Amps Line 1 field

begins blinking 88 (more than 10 seconds). Release the switch so 0Pt
appears. Reference Figure 10.

4. Press (and release) the Mode switch until PvrG appears.
5. Press the On/Off switch until a y appears, indicating Purge option is

Active.

6. Return to system purge display by pressing the Mode switch repeatedly

until the screen shown in Figure 11 is displayed. Purge will still be active.

Indicates whether the
generator is 0n or 0ff

Example of display with purge option set

Figure 11

e. Engage the Power Take-Off (PTO). (Note: Pump may sound rough for a few

minutes due to entrapped air.).

Advertising