Smart Power

®

Systems

A. C. MODULAR GENERATOR SYSTEM

Page 26 of 49

4.

If the system controller is powered on, but the generator is not running and no
buttons are pressed for 5 minutes, the system will enter Quiescent mode. In
Quiescent mode all displays are blank to conserve power. To return to Normal
mode from Quiescent mode, press the Mode switch.


5.

Whenever the PTO is engaged and the system controller is in Normal or Quiescent
mode, the generator can be switched from an “off” state to an “on” state, and vice-
versa, by pressing the “on/off” switch on the Command & Control Center. If the
PTO is not engaged, the hydraulic pressure is too low, or the generator enclosure
cover is not closed when the “on/off” switch is pressed, the following two screens
will be displayed alternately (reference Figure 15):

Example of low hydraulic pressure display

Figure 15


6.

If the system controller has been set to “auto-start”, the generator will begin to
produce power whenever the PTO is engaged. See installation instructions for the
directions to select the “auto-start” options.


7.

Additional Information provided by the Command & Control Center:

a. When the Command & Control Center is in Normal mode, pressing the Mode

switch once will display the oil temperature (reference Figure 16).


Displayed Oil
Temperature in degrees
Fahrenheit

Example of oil temperature display

Figure 16