Advanced reader functionality, Protocol support, Iso 18000-6c (gen2) – ThingMagic Astra-EX User Manual

Page 63: Advanced reader functionality 63, Protocol support 63, Iso 18000-6c (gen2) 63

Advertising
background image

Advanced Reader Functionality

M6 and Astra-EX User Guide

63

Advanced Reader Functionality

Protocol Support

Using the MercuryAPI ReadPlan classes the M6 and Astra-EX can be configured to
perform various Read operations. The following describes protocol specific configuration
options supported on the M6 and Astra-EX. See the MercuryAPI Programmers Guide and
language specific reference guides for details on supported Gen2 command functionality.

ISO 18000-6C (Gen2)

Protocol Configuration Options

The M6 and Astra-EX supports multiple ISO-18000-6C profiles including the ability to
specify the Link Frequency, encoding schemes, Tari value and modulation scheme. The
protocol options are set in the MercuryAPI Reader Configuration Parameters (/reader/
gen2/*). The following table shows the supported combinations:

ISO-18000-6C Protocol Options

Backscatter

Link Frequency

(kHz)

Encoding

Tari

(usec)

Modulation

Scheme

250

Miller (M=8)

12.5

PR-ASK

250

Miller (M=4)

12.5

PR-ASK

250

Miller (M=2)

12.5

PR-ASK

250

FM0

12.5

PR-ASK

250

Miller (M=8)

25

PR-ASK

250

Miller (M=4)

25

PR-ASK

250

Miller (M=2)

25

PR-ASK

250

FM0

25

PR-ASK

250

Miller (M=8)

25

PR-ASK

640

FM0

6.25

PR-ASK

Advertising
This manual is related to the following products:

M6