Power wiring – Tycon Power TP-SW8(-NC) User Manual

Page 5

Advertising
background image

User’s Manual

TP-SW8



TYCON POWER SYSTEMS

5

*PoE indicator (the left LED on RJ45)

LED

STATUS

Description

P1~P7

PoE PSE

Yellow

LED ON when PoE power output.

Off

No PoE output

P8

PoE PD

Yellow

TP-SW8:4 pairs power source receive.

TP-SW8-NC:2 or 4 pairs power source

receive.

Yellow

Blinking

TP-SW8:2 pairs power source receive.

TP-SW8-NC:unused.

Off

No power is detected on this port.

*Power wiring

The PoE switch accepts input voltage from terminal block (rear panel) or RJ45 cable (port 8). If

power input from terminal block, the input voltage must be in the range of 12 to 57 VDC. Input

current on secondary wire terminal input is 10A max. Input current on port 8 is 2A max.

If power input from the RJ45 cable (port8) in the TP-SW8, the input voltage must be in the range of

44 to 57VDC if running for 802.3af operation or 50 to 57VDC if running for 802.3at operation.

If the TP-SW8 is not powered within IEEE802.3af/at specification, it will only function as an

ethernet switch without PoE output.

The PoE PSE ports will deliver DC power over the spare pairs as the connection:

* TX on lines 1 and 2

* RX on lines 3 and 6

* V+ on line 4 and 5

* V- on line 7 and 8

The Port 8 may get power over the signal pair or spare pairs, the connection as:

* Data pair A plus V+ /V- on lines 1 and 2

* Data pair B plus V-/V+ on lines 3 and 6

* V+/V- on line 4 and 5

* V-/V+ on line 7 and 8