3 building and sending data frames – Campbell Hausfeld SDM-CAN User Manual

Page 37

Advertising
background image

Section 3. Programming CR10X, CR7 and CR23X

6: 6 Loc [ TC_1 ]

7: 1.0 Mult

8: 0.0 Offset

;Transmit Data on to CAN network

13: SDM-CAN (P118)

1: 0 SDM Address

2: 2 Time Quanta

3: 5 Tseg1

4: 2 Tseg2

5: 1 ID Bits 0..10

6: 0 ID Bits 11..23

7: 0 ID Bits 24..28

8: 20 Tx, unsigned int, LSB 1st

9: 1 Start Bit No.

10: 16 No. of Bits

11: 1 No. of Values

12: 6 Loc [ TC_1 ]

13: 1.0 Mult

14: 0.0 Offset

*Table 2 Program

02: 0.0000 Execution Interval (seconds)

*Table 3 Subroutines

End Program

The default setting for the SDM-CAN internal software switches is
0. The switches must be set by using the data type 32 parameter to
enable data transmission. Also remember to check the jumper
settings inside the SDM-CAN if enabling transmission, as the
default setting is for transmission to be disabled in hardware.

NOTE

3.5.3 Building and Sending Data Frames

The following table shows the parameters used for the process of using a series of
P118s to build a dataframe and then use a further call with data type set to 26 to
define part of the working buffer as a remote frame response:

Input Loc

Value

Data

type

Start Bit

nbits

Dec Hex Indexed

64

bit

Frame

Un-initialised frame>>

0x12abcdef12345678

170

0xaa 7 5 N

8 Loaded

into

frame>>

0x0000000000000aa0

1234

0x4d2 13 17 N

16 Ored

into

frame>>

0x0000000004d20aa0

65535 0xffff 13 31

N

7 Ored

into

frame>> 0x0000001fc4d20aa0

171

0xab 13 8 Y

8 Ored

into

frame>>

0xab00001fc4d20aa0

X

X

26

28

Y

32

Remote Response Frame>>

0x0ab00001 32 bit frame

3-19