Industrial Injection FORD 6.7L Compound Turbo User Manual

Page 21

Advertising
background image

Pg. 21

Step 13:

Install the aftermarket up-pipe provided in the kit using the factory 13mm nuts that where used to hold

the factory up-pipe to the exhaust manifold.

Connect the factory EGT sensor to the aftermarket up-pipe using a 16mm wrench.

Using a 7/16 wrench or deep socket you can re-install and tighten the V-Band clamp to the upper end of

the up-pipe

Step 14:

With the up-pipe in, install the provided head shield. You will see a reflective sheet of heat shield prod-

uct in the kit, it has a sticky back and will be used to line the upper side of the metal heat shield. Com-

plete this before putting the heat shield into the engine bay. Use a razor knife to trim accordingly.

Advertising