Troubleshooting, Troubleshooting 16 – Magnum Dynalab MD-109 User Manual

Page 16

Advertising
background image

TROUBLESHOOTING




PROBLEM

POSSIBLE CAUSE

POSSIBLE SOLUTION

No sound, meter
lights are not on

• Power cord

disconnected

• Power off at source
• Fuse blown

• Connect power cord
• Check AC source
• Check fuse in AC input

socket

No sound, meter
lights are on

• Interconnect not

properly installed

• Preamp set to wrong

source

• Power amp off
• Tube failure

• Check installation of

interconnects

• Turn preamp to

appropriate input

• Turn on amp
• Replace tubes (6922)

Signal strength is
low

• Antenna not connected
• Wrong type of antenna

• Station too far away
• Antenna pointed the

wrong way

• Check antenna hookup
• Check instruction

manual for types of
antennas

• Change your antenna
• Rotate the antenna to

point at the station

Reception is poor

• Antenna not connected
• Wrong type of antenna

• Cross talk from

neighboring stations

• Multi-path is occurring

• Check antenna hookup
• Check instruction

manual for types of
antennas

• Switch to narrow setting

on IF bandwidth

• Rotate your antenna,

read the

Reception

Techniques

Intermittent sound

• Mute switch is off

• Turn mute switch on


- 16 -

Advertising