8. DRAWER KICK-OUT CONNECTOR AND POWER CONNECTOR

8.1 Specifications of Drawer Kick-Out Connector

8.1.1 Drawer Kick-Out drive signal

A pulse specified by ESC p, DLE DC4 is output. In parallel interface mode, the
SW(+) state can be confirmed at No. 34 pin of the interface connector or by the
DLE EOT, GS a and GS r commands at the serial/parallel interface.

8.1.2 Electrical characteristics

• Drive voltage: DC 24 V
• Drive current: 0.8 A maximum (Within 510 ms)
• SW signal:

Signal level “L” = 0 to 0.5 V

“H” = 3 to 5 V

8.1.3 Connector Pin Configuration

Connector used:

TM5RJ3-66 (Hirose) or equivalent

Applicable connector: TM3P-66P (Hirose) or equivalent

CAUTION:

• No output is produced while printing.
• The drawers 1 and 2 cannot be driven simultaneously.
• A solenoid used for the drawer should be of 36

or more. The output current should

be kept at 0.8 A or less; otherwise, breakdown or burning could occur.

• This connector cannot be connected to a telephone line. Do not connect to anything

other than the solenoid.

6

1

Signal

No.

1

2

3

4

5

6

FG

DRAWER 1

DRSW

VDR

DRAWER 2

GND

Frame Ground

Drawer 1 drive signal

Drawer switch input

Drawer drive power supply

Drawer 2 drive signal

Common ground on circuits

Function