Appendix c rs-232 communication protocol, Protocol command – Zigen AX-88 Audio User Manual

Page 52

Advertising
background image

Matrix Switching System—User Manual

51

Appendix C RS-232 Communication Protocol

This AV Matrix RS-232 communication protocol uses variable length bytes of information

as define below. The default baud rate is 9600 bps, no parity, 8 data bit and 1 stop bit.

Command timeout is 300 ms, and byte to byte timeout is 30ms.

Use the RS-232 connecting cable to connect the computer serial port to the RS-232

communication port of the matrix device. The computer can control the matrix device via

RS-232. Aside from using the front panel keys for operation, you are also permitted to

use the RS-232 connection port for remote operation.

Protocol Command

A. Standard Command

Standard command is 5 bytes command.

Device + Request + Index + Value + CRC

Byte 1: Device Byte (DB)

Byte 2: Request Byte (RB)

Byte 3: Index Byte (IB)

Byte 4: Value Byte (VB)

Byte 5: CRC Byte (CB)

B. Variable Length Command

Variable length command is 2n+4 bytes command.

Device + Request + Length + Index 1 + Value 1 +

… + Index n + Value n + CRC

Byte 1: Device Byte (DB)

Byte 2: Request Byte (RB)

Byte 3: Length Byte (LB)

Byte 4: Index 1 Byte (IB

1

)

Byte 5: Value 1 Byte (VB

1

)

Byte 6: Index 2 Byte (IB

2

)

Byte 7: Value 2 Byte (VB

2

)

… … … … …

Byte 2n + 2: Index n Byte (IB

n

)

Byte 2n + 3: Value n Byte (VB

n

)

Byte 2n + 4: CRC Byte (CB)

Host must send CRC code to follow the last byte.