Via 10 Active X Controls

VIP ActiveX control

Control Name: Via10VIPX

Description: Interface to Via 10’s VIP Port to read switches, pots, temperature sensors, other logic outputs…

Design Time Parameters:

Addr

Via 10’s IP Address

AutoUpdate

0 = Manual VIP update only, -1 = Get VIP values automatically

UpdateFreq

Number of milliseconds between auto updates

Runtime Parameters:

VIP1

0 – 255 = Value of VIP 1

VIP2

0 – 255 = Value of VIP 2

VIP3

0 – 255 = Value of VIP 3

VIP4

0 – 255 = Value of VIP 4

VIP5

0 – 255 = Value of VIP 5

VIP6

0 – 255 = Value of VIP 6

VIP7

0 – 255 = Value of VIP 7

VIP8

0 – 255 = Value of VIP 8

Key Methods:

DoConnect

Initialize a connection to the Via 10

DoDisconnect

Break connection to Via 10

RequestVIP

Manually request VIP update

Events:

OnVIP1Change

Value on VIP 1 input changed

OnVIP2Change

Value on VIP 2 input changed

OnVIP3Change

Value on VIP 3 input changed

OnVIP4Change

Value on VIP 4 input changed

OnVIP5Change

Value on VIP 5 input changed

OnVIP6Change

Value on VIP 6 input changed

OnVIP7Change

Value on VIP 7 input changed

OnVIP8Change

Value on VIP 8 input changed

OnConnect

Connection to Via 10 started

OnDisconnect

Connection to Via 10 stopped

Initialization:

DoConnect

must be called to initialize a connection to the Via 10

VOP ActiveX control

Control Name: Via10VOPX

Description: Interface to Via 10’s VOP Port to drive relays, lamps or LEDs, other logic input ports…

Design Time Parameters:

Addr

Via 10’s IP Address

AutoSend

0 = Manually send VOP Changes, -1 = Automatically send VOP Changes