background image

Phone Line Specifications

Page 14 of 16

Talk-A-Phone Co.

H. The user is cautioned that any changes or modifications not expressly

approved by the party responsible for compliance could void the user’s

authority to operate the equipment.

I. The Talk-A-Phone Co. U. S. A. Service Center is located at 5013 North Kedzie

Avenue, Chicago, Illinois 60625-4988, telephone number (773) 539-1100, fax

number (773) 539-1241.

IX. Phone Line Specifications

A. MODE I Operation

The following criteria must be met by a phone line to insure proper

functionality of the FCC approved equipment. All voltages use Tip as ground

when measuring.
1. On-Hook voltage must be less than or equal to –36 V (-50 V standard).
2. Off-Hook should be recognized in a maximum time of 300 ms.
3. At an Off-Hook voltage of –15 V, the current that is supplied must be no

less than 20 mA and no more than 120 mA.

4. Dial tone must consist of 350 Hz and 450 Hz tones at –17 dB ± 0.5%.
5. The telephone line must generate Ring-Back consisting of 440 Hz and 480

Hz tones at –17 dB ± 0.5%, with a duty cycle of 1.6 seconds on—4.8 seconds

off ± 10% interrupted at 20 Hz.

6. The telephone line must generate a busy signal consisting of 480 Hz and 620

Hz tones at –17 dB ± 0.5%, with a duty cycle of 500 ms on—500 ms off.

7. The telephone line must be able to recognize or send the following

frequencies in order to decode or transmit DTMF:
a) 685 Hz — 709 Hz

Row 1

b) 757 Hz — 784 Hz

Row 2

c) 837 Hz — 867 Hz

Row 3

d) 925 Hz —957 Hz

Row 4

e) 1189 Hz — 1229 Hz

Column 1 (1, 4, 7, *)

f) 1314 Hz — 1358 Hz

Column 2 (2, 5, 8, 0)

g) 1453 Hz — 1501 Hz

Column 3 (3, 6, 9, #)

h) 1607 Hz — 1659 Hz

Column 4 (A, B, C, D)

8. When dialing, the telephone line should require a minimum tone pulse ON

time of 40 ms, as well as a minimum between tone gap of 40 ms.

9. The telephone line should support and match with a 600 AC impedance,

as well as a DC resistance of 100  — 200 .

B. MODE II and MODE III Operation

Talk-A-Phone phones can be used with most PBX systems with non-standard
dial tones, ring-backs, busy signals and hang-ups.