D. Code Summary

Command Function

*31* …[up to 8 digits]*

Guard Access Code entry for phone programming
(Default Code is *31**)

*30* …[up to 8 digits]*

Master Access Code entry to change Guard Access Code or Master

Access Code (Default Code is *30*12345678*)

*30*14725836*

Resets Consolidator programming to factory defaults

*32* …[up to 8 digits]*

Programs and stores a new Master Access Code

*33* …[up to 8 digits]*

Programs and stores a new Guard Access Code

*34* …[up to 2 digits]*

Sets number of rings before EC-8 picks up when it is dialed

*62*

Remote Mode (default)

*37* Local

Mode

*63* Day/Night

Mode

*35*

In Day/Night Mode, call LOCAL PHONE then TELCO IN

*36*

In Day/Night Mode, call TELCO IN then LOCAL PHONE

*39*...[1 or 2]*

Program the type of phone line in the TELCO IN
*39*1* for ordinary phone lines (default)
*39*2* for PBX lines

*4...[1-8]*

Routes to emergency/information phone in phone jack number 1-8