Talkaphone PBX-64 User Manual

Pbx-64 analog and ip phone system installation

Advertising
background image



PBX-64 Analog and IP Phone System Installation

Copyright 2009 Talk-A-Phone Co. All rights reserved.


Talk-A-Phone

Co.

• 7530 North Natchez Avenue • Niles, Illinois 60714-3804

Rev. 7/27/09

Phone 773.539.1100 • Fax 773.539.1241 • [email protected] • www.talkaphone.com

All prices and specifications are subject to change without notice.

Talk-A-Phone, Talk-A-Lert, Scream Alert and WEBS are registered trademarks of Talk-A-Phone Co.

I. Introduction

This PBX system is specially designed to accommodate Talk-A-Phone Emergency/Information Phones, both
analog and VoIP. Versatile and robust, these full-featured PBXs provide a complete head-end solution.

Each of these PBX systems ships preprogrammed from the factory per the requirements specified on the
submitted preference form.

Note:

Do NOT adjust any dipswitches or settings that are not outlined in the Installation Instructions. Talk-A-Phone
authorization is required for adjustment of such dipswitches and settings.

Iwatsu technical/installation documents may have been provided with this PBX Installation document. These Iwatsu
technical/installation documents are to be used only as a reference. Do NOT follow instructions on Iwatsu documents
unless instructed by a Talk-A-Phone technician.

II. Core

Components

Qty.

Iwatsu

Part No.

Description

1 IX-CME

Gateway

Controller

Cabinet

1 IX-PWSE

Main

Power

Supply

1

IX-408

8-Port

Digital

Station / 4-Port Trunk Card

1

IX-12KTD-3

Digital

Attendant

Phone

1 IX-CCU

Central

Control

Unit

Card

1

IX-CCSU

Central Control Sub Unit Card

III.

General Hardware Installation

To install the PBX-64 Phone System, after site preparation (including provision of power and CO / PSTN lines),
follow these steps:

1. Install the IX-PWSE Power Supply into the dedicated slot on the left side of the IX-CME by sliding it

between the left and right guide rails located on the lower shelf bracket. Make sure that the power
supply is inserted deep enough so that all of the connector pins make complete contact with those on
the backplane motherboard. Make sure the AC power cable attached to the IX-CME is pulled out to
the left and for easy access after power supply installation.

2. Secure the IX-PWSE to the upper and lower shelf brackets with two black zinc plated screws

provided with the IX-CME.

3. Ensure the green ground wires attached to the IX-PWSE are secure in place with the star washer

between the screw and the metal end of the green ground wire (Factory installed).

4. Mount the IX-CCSU daughterboard to the IX-CCU card by matching the CNCCSU1 to CNCCU1

connectors and CNCCSU2 to CNCCU2 connectors on the IX-CCU card and the IX-CCSU card
respectively.

5. Slide the IX-CCU/IX-CCSU cards into the slot marked CCU/CCSU at the bottom of the IX-CME

cabinet. Make sure that the card is inserted deep enough for all the connector pins to make complete
contact with those of the backplane motherboard. Secure the card stopper bracket (located next to
the left locking tab) with the screw provided.