Pcs-84-10 installation instructions – Talkaphone PCS-84-10 Power Charging System (84 Ah) User Manual

Page 2

Advertising
background image

PCS-84-10

Installation Instructions

Copyright 2012 Talk-A-Phone Co.

• 7530 North Natchez Avenue • Niles, Illinois 60714 • Phone 773.539.1100 • [email protected] • www.talkaphone.com.

All prices and specifications are subject to change without notice. Talk-A-Phone, Scream Alert, WEBS and WEBS Contact are registered trademarks of Talk-A-Phone Co. All rights reserved.

Page 2 of 3

2. If using an optional ETP-CI , connect the 12VDC side of the DC/DC Converter to the Battery, and plug the

barrel connector into the ETP-CI Cellular Interface.

3. If using a VOIP-500 Series Phone, connect the device directly to the battery. Make sure the phone is set to

accept 12VDC by adjusting the jumpers on the PCB. Refer to the phone installation instructions for further
information.

4. If using an optional VOIP-RF-FM-1100, connect the PoE injector (model VOIP-RF-FM-POE) directly to the

battery.

5. Connect the battery charger to the battery.
6. If 120VAC is available, connect the battery charger to the incoming 120V. If a PCS-SD Series step down

transformer is used to step down a higher incoming voltage, connect the 120V side of the Battery Charger
to the 120V side of the transformer, and connect the incoming high voltage to the high voltage side of the
transformer.

7. Phones and Cellular/Wireless IP Interfaces require additional programming as described in their own

manuals.

Figure 1.

Wiring Schematic for a typical Power Charging System

IV. Physical Installation

The Power Charging System can mount into a PCS-BOX series enclosure, a Talk-A-Phone tower enclosure (ETP-
MT/R-PCS, ETP-MT/R-PCS-WP, ETP-MTE-W, ETP-MTE-WP and WEBS-MT/R
) or surface mount enclosure (ETP-
SMW
), or can be installed into a customer supplied enclosure.


Advertising