If your transponder requires parallel Gray
code input, and you wish to use the EFIS-D60
as your altitude encoder, you will need to
purchase Dynon Avionics’ Encoder Serial-to-
Parallel Converter. Please refer to page 5-13
for more information on the installation of
this option.

Also, do not have your EFIS-D60 plugged into the USB-to-Serial adapter while installing the
driver.

Altitude Encoder Wiring

The EFIS-D60 outputs its altitude
measurements in one of four standard serial
outputs and is readable by many modern
transponders. The EFIS-D60 will function
properly whether or not this altitude encoder
functionality is used. To use the EFIS-D60‘s
altitude encoder functionality, simply wire
the 2 encoder connections (GND and
Encoder Transmit) from the DB25 connector to their
respective connections on your transponder.
Per ATC/FAA requirements, the serial encoder output
of the EFIS-D60 reports pressure altitude, which, by
definition, is indicated altitude when the baro is set to
29.92. So, when you set your EFIS-D60‘s baro
adjustment to 29.92, its indicated altitude will match
the altitude that is being reported to your transponder.
There are four different serial formats used by
transponders. The EFIS-D60 can output any of these
formats. To select which format the EFIS-D60 sends out its serial encoder output port, you must
choose the appropriate format via the menu system. When the menu system is displayed, push
the following sequence of buttons: SETUP > ALTENC. When in the Altitude Encoder Setup
menu, you can toggle the resolution of the output between 10 and 100 feet; this accommodates
some transponders which can input and display altitude in 10 foot increments. In this menu, you
can also select between the four different output formats, which are described below.
Dynon’s supplied EFIS harness has a serial altitude encoder cable which consists of 2
conductors, surrounded by a metal shield and white insulation. Dynon has shipped harnesses
with different colors for Encoder serial transmit line. Determine your connections using the table
above. Connect the Encoder serial transmit to your transponder’s serial input or to Dynon’s
Serial-to-Parallel Converter as described in the Encoder Serial-to-Gray Code Converter
Installation section on page 5-15
in the Appendix.

EFIS

DB25

pin# Function Wire color

13

Encoder

serial

transmit

Blue/White

(or black)

21 Ground White