Contacts, Contacts -19, The contacts – Dynon Avionics EMS-D120 Installation Guide User Manual

Page 59

Advertising
background image

EMS

Configuration

Contacts

Note that while contacts are shown below the HS34 INPUTS section, they are not available until
you purchase and connect an HS34 expansion module. Ensure you are configuring in either of
the two EMS CONTACT menus.

To access the CONTACTS configuration page, select EMS > SETUP > SENSOR > EMS
CONTACT 1 or CONTACT 2.
Select the alarm mode as described in the
Alarm and Color Threshold Configuration
section on page 5-2. Contacts can only be
configured as an INFO ITEM. Configure the
contacts info item to display in the desired
location(s), as described in the EMS-D120
Pilot’s User Guide > Global Configuration
Settings > Info Item Configuration section.
Press DOWN▼ to select the NAME field.
The first character of the 4-character name is
highlighted. Press INC+ or DEC- to cycle through the numbers and letters for the first character.
When you have selected the desired letter, press SEL► to move to the next character. Repeat
this for each of the characters in the contact name field.
Press DOWN▼ to select CLSD LABEL. The label you enter here will be shown
when CONTACT (1 or 2) is closed (connected to ground). Select CLSD COLOR
and press SEL► until the desired color for a closed contact is displayed. Repeat
these two steps for OPEN LABEL (label shown when contact is disconnected from
ground) and OPEN COLOR.
Contact alarm triggering is based on the color selected in the COLOR field for either
of the states. If you have selected a SELF-CLEAR or LATCHING alarm for a
contact and it enters a state selected to be RED, the EMS will display the alarm bar
and the contact label will blink onscreen.

The Contact Inputs listed below the HS34 INPUTS section, (HS34 CONTACT 1, 2, 3, 4)
can only be used with an HS34 installed and configured.

EMS-D120 Installation Guide

5-19