Appendix d: ems-d120 specifications, Appendix d: ems-d120 specifications -4 – Dynon Avionics EMS-D120 Installation Guide User Manual

Page 70

Advertising
background image

Appendix

7-4

EMS-D120

Installation

Guide

Appendix D: EMS-D120 Specifications

Mechanical

6.95” wide x 4.90” tall x 4.51” deep (177 x 125 x 115 mm)

Operating

Temperature

-22° to 122° F (-30° to 50° C)

Power

Voltage:

10 - 30 Vdc

Power:

12 watts typical; 14 watts maximum

Connections

Wiring:

DB25 female & DB37 male connectors

Screen

Type:

AMLCD, TFT (Thin Film Transistor)

Backlight:

400 nits (or 800 nits, for super-bright option)

Size:

7.0” diagonal (178 mm)

Resolution:

854 x 480 color pixels

Sensor Inputs

6 - EGT (Type K Thermocouple)
6 - CHT (Type J Thermocouple)
2 - Fuel Level (Resistive or Capacitance with 5 volt output)
2 - RPM (P-lead or pickup)
2 - Contacts
1 - Manifold Pressure (voltage)
1 - Oil Temperature (Resistive)
1 - Oil Pressure (Resistive)
1 - Fuel Pressure (Resistive)
1 - Fuel Flow (Frequency)
1 - Current (Shunt)
1 - Voltage (from supply power)
1 - Turbine Inlet Temperature (Type K Thermocouple)
3 - General Purpose (Either resistive or voltage for OAT, Fuel

Tanks 3&4, Coolant Temp, Coolant Press, Carburetor
Temp)

Inputs/Outputs

1 - Alarm Light Contact
1 - Audio Alarm
1 - RS-232 bidirectional PC communication
1 - RS-232 data input (GPS, SL30, etc.)
1 - Dynon Smart Avionics Bus (DSAB) differential

Advertising