Operation, Radiance natural vent gas heater – Vermont Casting 3349 User Manual

Page 16

Advertising
background image

16

16

Radiance Natural Vent Gas Heater

20004409

Operable Doors

The Radiance is shipped with the operable door front.
The stove may be operated with the doors either open
or closed. To open the front doors, insert the handle
into the door latch stub and turn it to the right and up.
(Fig. 31) When not in use, the handle may be stored in
the handle holder on the right side of the rear shroud.
(Fig. 32)

Operation

Your First Fire

Read these instructions carefully and familiarize
yourself with the burner controls shown on Page 16.
Locate the pilot assembly, Figure 33. Follow the
lighting instructions on Page 17 exactly.

During the first fire, it is not unusual to smell some odor
associated with new logs, paint and metal being
heated. Odors should dissipate within an hour or so,
however, you can open a window to provide fresh air to
alleviate the condition.

Pilot and Burner Inspection

Each time you light your heater check that the pilot
flame and burner flame patterns are as shown in
Figures 35 and 36. If flame patterns are incorrect, turn
the heater off. Contact your dealer or a qualified gas
technician for assistance. Do not operate the heater
until the pilot flame is correct.

Flame & Temperature Adjustment

For units equipped with HI/LO valves, the flame adjust-
ment is accomplished by rotating the HI/LO knob located
near the center of the gas control valve. (Fig. 34)

Fig. 36 Correct burner flame pattern.

Red Glow

LG157

Fig. 31 To open the front doors, turn handle
counterclockwise.

Clockwise
to Close

Counterclockwise
to Open

ST621a

RADIANCE

Handle
Holder

ST656

Fig. 30 When not in use, store handle in the handle holder.

LO

HI

Turn

counterclockwise

to decrease

flame height

Turn clockwise

to increase

flame height

HV102

Fig. 34 Flame adjustment knob for Honeywell valve.

Fig. 33 Pilot Assembly location.

ST476

Pilot Assembly

CO105c

Fig. 35 Correct pilot flame pattern. SIT pilot.

Flame Characteristics

It is important to periodically perform a visual check of
the pilot and burner flames. Compare them to Figures
35 and 36. If the flame patterns appear abnormal
contact a qualified service provider for service and
adjustment.

Advertising
This manual is related to the following products: