Radiance natural vent gas heater, Fuel conversion instructions, Conversion precautions – Vermont Casting 3349 User Manual

Page 19: Conversion procedure

Advertising
background image

19

Radiance Natural Vent Gas Heater

20004409

Fuel Conversion Instructions

WARNING! This conversion kit shall be installed
by a qualified service agency in accordance with
the manufacturer’s instructions and all applicable
codes and requirements of the authority having
jurisdiction. If the information in these instruc-
tions is not followed exactly, a fire, explosion or
production of carbon monoxide may result
causing property damage, personal injury or loss
of life. The qualified service agency is respon-
sible for the proper installation of this kit. The
installation is not proper and complete until the
operation of the converted appliance is checked
as specified in the manufacturer’s instructions
supplied with the kit.

CAUTION: The gas supply shall be shut off prior
to disconnecting the electrical power, before
proceeding with the conversion.

PILOT

O

N

OFF

PILOT

ADJ

LO

HI

Main
Gas Line

Gas Supply Inlet

ST226

Fig. 37 Attach the gas line to the left side of the valve.

Conversion Precautions

This conversion must only be completed by qualified
personnel. Before proceeding, turn control knob on
valve to OFF and turn gas supply OFF. Turn OFF any
electricity that may be going to the appliance.
Caution: Allow stove to cool completely before begin-
ning conversion.

Conversion Procedure

1. Remove stove front. Lift stove front up and then

swing bottom out and away to disengage from the
stove body. (Page 22, Fig. 44)

2. Undo the right and left latches at the top of the glass

frame. (Page 22, Fig. 45)

3. Pull the top edge of the glass and frame assembly

away from the firebox face. Place the assembly out
of the way on a flat, padded surface such as a
counter protected by a towel.

4. Remove the logset from the firebox.

5. Remove the rear log bracket by unfastening the

screw and pulling the bracket away. (Fig. 38)

6. Remove the right and left log bracket assembly by

unfastening the two screws which hold the burner in
place. (Fig. 38)

Remove Screws

Rear Log Bracket

Pilot

Left & Right Log
Bracket Assembly

ST350

Fig. 38 Remove rear log bracket and left and right log bracket
assembly.

7. Hold the burner at the right hand side and lift to clear

the right burner leg. Then pull to the right to clear the
injectors on the left hand side.

8. Remove injector orifices from left burner leg using

1/2” wrench. (Fig. 39)

9. Install conversion orifices. (Refer to Table 1)

10. Remove cap from HI/LO knob. This can be accom-

plished by lifting the plastic cap off the screw. (Fig.
40)

11. Remove the screw from center of HI/LO knob with

small screwdriver turning counterclockwise. (Fig. 40)

Fig. 39 Remove and replace injector orifices.

90¡

Left Burner Leg

Injector Orifices

ST353a

L O

HI

L O

HI

Cap

Hi-Lo
Knob

Lift Open

Center Screw

CO100

Fig. 40 Remove center screw from HI/LO knob.

Advertising