8310 User Manual

••••

(V 1.0.1)

Category

Parameter

Specification

Level

1Vpp nominal

Signal

Analog video sync (black burst or tri-level), or

AES/EBU DARS

Impedance

75

terminating

Return Loss

>30dB to 30MHz

Max DC on Ref Input

±1V

Alarm Indicator

ANSI/SMPTE 269M-1999 contact closure

Connector

Female BNC

Max Voltage

24V DC

Max Current

20mA

Loss of AC input power

Alarm Conditions

DC output voltage error

DC output voltage

DC output current

Critical temperature

PS Monitored Parameters
(-C version only)

PS-8300 fan failure

Backplane rail voltage

Cooling fan failure

Frame Monitored Parameters
(-C version only)

Ambient temperature

System fault LED

Fan failure LED

Frame controller audio alarm

SMPTE Fault
Reporting

Alarm Indicators
(-C version only)

Frame door audio alarm

Ambient temperature range

0 ºC to 40 ºC

Environmental

Humidity, non condensing

<95%