Dip switches on the mfc-8310-n, Dip_1 switch, Dip_2 to dip_7 switches – Cobalt Networks OPENGEAR PS-8300 User Manual

Page 32: Dip_8 switch, Buttons on the mfc-8310-n, Alarm mute/bootload button, Reset button, Mfc-8310-n leds

Advertising
background image

Page 32 of 40

8310 User Manual

••••

(V 1.0.1)

DIP Switches on the MFC-8310-N

The following DIP Switches are located on the MFC-8310-N controller card.

DIP_1 Switch

DIP_1 switch disables the audio alarm signal as follows:

ON — This setting disables the audio alarm.

OFF — This setting enables the audio alarm.

DIP_2 to DIP_7 Switches

DIP_2 to DIP_7 switches are not used.

DIP_8 Switch

DIP_8 switch sets the default IP Address of the MFC-8310-N controller card as follows:

ON — This setting enables the card to use the default IP Address of 192.168.1.1.

OFF — This setting enables the card to use the IP Address configured by the user.

Buttons on the MFC-8310-N

The following buttons are located on the MFC-8310-N controller card.

Alarm Mute/Bootload Button

When a card in the frame is reporting an error, pressing the Alarm Mute Button will mute the audio
alarm until another fault condition occurs. This button is also used as a bootload button for factory
service in the unlikely event of a complete card failure. The bootload process is further described in
pages 36-37, Service Information.

Reset Button

This button is used to restart both of the onboard processors: the fan control processor and the
communications processor. The communications processor requires approximately 30 seconds to
restart and re-establish network communications.

MFC-8310-N LEDs

The front edge of the MFC-8310-N, and the CFM-8310 in the frame door, have LED indicators for
cooling module fan, alarm, and communication activity.

The CFM-8310 provides LED and Alarm switching controls to the front edge of the 8310 frame door.

LED displays and descriptions are provided in the following table:

Advertising