PROBLEM SOLVtNO

Am

/

CARE_____________ ____________

Information Codes

When something unusual occurs, the display may show one of the information codes
below. These will help you fix the problem.

Information

code

Meaning

Action

010

No recording paper.

Reload recording paper

(see page 62).

020

Thermal Recording Head
temperature is too high.

Open the Receiving Unit for

a few minutes to permit
cooling.

030

Document misfeeding.

1. Reload the document

properly.

2. Remove document jam.
3. Adjust ADF (see page 67).

031

Document paper is too long

or jammed.

Document length exceeds
1 meter.

Remove document jam

(see page 64).

060

Door is opened.

Close the Receiving Unit.

400

During initial handshake,
receiving station did not
respond or communication
error occurred.

1. Check with the other

party.

2. Reload the document

and try again.

402
404
405

During initial handshake,
communication failure
occurred.

Reload the document and try

again.

403

No polling capability at the

other side.

Ask other side to set

“POLLED « ON”.

407

No confirmation from the
receiving station for the
previous page sent.

Wait a few minutes and send

again.

408
409

Other side confirmation of

previous page is illegible.

Walt a few minutes and
transmit again.

411
414

Polling password does not
match.

Check polling password.

60