FUNCTION: Core Charging

PROBLEM: Unit Charges Improperly

Place heat storage switch in the "On" position. Place charge level switch in the "Low/Auto" position. Turn thermostat

all the way down (counter clockwise) to the low stop position. Energize heater, ensure that proper line voltage is present

at L1 to L2 and F1 to F3. Remove the wiring from the charging disks and put jumpers in their place (white to gray,

orange to gray, and yellow to gray). Jumper the blue and blue/white peak control wires.

IS THE AMBER

CHARGING

LIGHT ON?

Check voltage

at T1 to T2.

Remove the jumper

between the white

and gray wire.

Does the charging

light turn off?

Check voltage at

T2 to L2.

Check voltage at

L2 to T1.

Check unit wiring.

Place the charge level switch in the "Med" position. Does the

charging light turn on?

Remove the jumper between the yellow and gray wire. Does the

charging light turn off?

Place the charge level switch in the "High" position. Does the

charging light turn on?

Remove the jumpter between the orange and gray wire. Does the

charging light turn off?

Turn up the room thermostat. Does the charging light stay off?

Change charging

disks(61,62,63).

Check voltage at

L2 to T1.

Is heater hot?

No Line

Voltage

Yes

Yes

Yes

Yes

Line Voltage

Fix unit

wiring.

Replace circuit

board (29).

Incorrect

Replace linear

high limit (33).

Yes

No

Yes

Correct

No Line

Voltage

No Line Voltage

No

No

No

No

Check the ohm value

of the elements(54).

Yes

Line

Voltage

Line

Voltage

No

No Line Voltage

No

Line Voltage

Yes

No

Change elements (54).

NOTE: If elements are open, change the charging disks (61,62,63) as well.