Steffes 612EXT Troubleshooting Guide User Manual

Page 7

Advertising
background image

DISCHARGE AIR

TOO COOL

Check for adequate core

temperature.

Check for damper

jamming or

obstruction.

Refer to "Unit Charges

Improperly" flow chart

on Page 2 of this manual

to troubleshoot.

Check bimetallic coil

assembly (39) for

proper calibration (see

note below).

Repair or replace

fan assembly (47).

Problem

Present

Check unit for proper amperage

draw and refer to "Unit Charges

Improperly" flow chart on Page

2 of this manual to troubleshoot.

OK

MODEL: EXT

FUNCTION: Air Delivery

PROBLEM: Discharge Air too Cool

Before starting any procedures listed below, check room thermostat and circuit breaker settings.

NOTE: For cross reference to number coded components, refer to the Exploded View Diagram.

NOTE: To test the bimetallic coil assembly, it must be

completely cold. Either allow room unit to cool completely or

remove fan assembly and cool to room temperature. Once the

coil is cold, disconnect the damper linkage and let the bimetallic

coil go to its relaxed position. The bimetallic coil on units

equipped with air deflectors should be calibrated at a 90 degree

angle from the front of the fan assembly. The bimetallic coil of

units not equipped with an air deflector are calibrated at a 65

degree angle from the front of the fan assembly. Use the

cutout gauge on the left for checking this calibration. (To

determine whether the unit is equipped with an air deflector,

these deflectors would be located in fan assembly behind

bitmetallic coil.

OK

Page 6

Problem with

Core Charging

OK

Recalibrate

bimetallic coil.

Out

of Calibration