Operating the heater – Steffes 2006 User Manual

Page 10

Advertising
background image

Manual Charge Control

If manual charge control is being used, the owner must periodically adjust the brick core charge level setting
during the heating season in relation to outdoor temperature and the heating requirements of the area. To adjust
the brick core charge level, do the following:

Step 1

Press and hold the M button until a green bar appears on the MODE digit of the control panel face
plate next to room setting. Release the button.

Step 2

Press the M button again. The green bar on the MODE digit of the control panel face plate will
move to indicate storage setting can be adjusted. Core charge level set point is displayed on the
TEMPERATURE digits.

Step 3

Press the

or

arrow buttons to adjust the core charge level set point. The core charge level can

be set to any data value from 00 through 10.

00 = no core charging will occur
05 = 50% core charge will be maintained
10 = maximum core charge will be maintained

The face plate will automatically return to displaying current room temperature a few seconds after
making an adjustement.

HOW TO TURN THE HEATER "OFF" AND "ON"

You may wish to turn the heater off during the summer months. Brick core charging and room temperature
sensing can be turned off without disconnecting power to the heater.

Using Automatic Charge Control

Step 1

To turn the heater "OFF", use the

arrow button to decrease the room temperature set point until

the control panel face plate displays "OFF".

Step 2

To turn the heater back "ON", press the

arrow button to adjust room temperature to the desired set

point.

Using Manual Charge Control

Step 1

To turn the heater "OFF", hold the M button until room temperature set point appears on the TEM-
PERATURE digits of the face plate.

Step 2

Use the

arrow button to decrease the room temperature set point until the control panel face plate

displays "OFF".

Step 3

To turn the heater back "ON", press and hold the M and the

arrow buttons at the same time.

When room temperature set point displays on the face plate, let go of the M button. Use the

arrow button to adjust room temperature to the desired set point.

Operating the Heater

(cont'd)

9

4

The outdoor sensor will monitor outdoor temperature and provide the information to the heater. The heater will
respond by storing heat in the brick core accordingly. The outdoor temperature at which brick core charging in
the heater is to begin and the outdoor temperature the heater should be at full brick core charge may be adjusted
at the time of installation. The heater comes factory preset to start charging at 60

o

F (15.6

o

C) and to be at full

brick core charge at 20

o

F (-6.67

o

C).

Advertising