ROOM HEATING UNIT IDENTIFICATION LABEL

All heaters are UL and cUL safety listed. The listing identification label is located on the lower
left side panel of the heater.

Heater Wiring

1

17

Model

Charge Crct #1

S/N

Charge Crct #2

Options

Fan/Cntrl Crct

U.S. Patent #5.042.081

VAC

Watts

Temp Cntrl Crct

Steffes Corporation, Dickinson, ND

Manufactured in North America

Electric

Air Heater

L

U

L

U

C

LISTED

3P23

FIGURE 11

2

ROOM HEATING UNIT UMBILICAL CORD

(WIRING HARNESS) COLOR CODE

TABLE 1

WIRE COLOR

CIRCUIT DESCRIPTION

Black

Models 2002 & 2003: All heating elements.
Models 2004, 2005, & 2006: Upper heating elements.

Red

Models 2004, 2005, & 2006: Lower heating elements.

Blue

Blower and control circuit.

Refer to the Unit Identification Label on the lower left side of room heating unit
for proper blower and heating element voltages. (See Figure 11.)

Disclaimer:

The field connection wire and breaker size guide reflects only the code interpretation of Steffes
Corporation. It is the responsibility of the installer to follow all applicable codes and regulations for
the installation.

Models 2004, 2005, and 2006 units are equipped with a two-circuit element feed option. If dual feed is used,
refer to the Unit Identification Label located on the left side panel for proper sizing of each circuit. (See Figure
11.) If single-feed connection is used, size circuit for total wattage. (Charge Circuit #1 + Charge Circuit
#2 = Total Wattage.)

3

FIELD CONNECTION WIRE AND CIRCUIT BREAKER

SIZING GUIDE

#14 AWG

2.8

3.3

2.4

15

#12 AWG

3.8

4.4

3.3

20

#10 AWG

5.7

6.6

4.9

30

#8 AWG

7.6

8.8

6.6

40

#6 AWG

11.5

13.2

9.9

60

MAXIMUM CIRCUIT

WIRE SIZE

240VAC

277VAC

208VAC

BREAKER SIZE (240V Only)

Use copper wire rated at 75

o

C minimum only.

MAXIMUM kW

TABLE 2

NOTE

NOTE