PLACEMENT AND CLEARANCES

SET-UP

The area in which the Comfort

Plus is installed must remain

free of debris and room air

should be maintained at less

than 85

o

F.

A Back and Sides = 3 inches from combustibles

B Front = 36 inches

C Top = 6 inches from combustibles

D Bottom = zero clearance

E Outer Sides of Return and Supply

Ducts = zero clearance

F Between Duct and Left Side = 2 inches

Quick Reference Installation Guide

COMFORT PLUS

Models 4120, 4130, 4140

“Manufactured in North America”

3

BRICK LOADING

F

FRONT VIEW

(4100 Series)

FILTER TRAY

E

P
M

M

A

M

STEFFES

E

C

B

TOP VIEW

A

(4100 Series)

FR

ON

T O

F U

NIT

HALF BRICK

NOTCH IN BRICK

4120: Load in row 5

4130: Load in row 4 and 8

4140: Load in row 6 and 12

WARNING

WARNING

WARNING

WARNING

WARNING

1

1. Remove heating elements from base.

2. Place system in desired location.

3. Adjust leveling legs to prevent rocking.

4. Remove painted front panel of brick

storage cabinet.

5. Position element wiring harnesses to

avoid damage during brick loading.

6. Disconnect brick core temperature

sensor(s) from shipping position.

Position sensor(s) to avoid damage

during brick loading.

7. Remove galvanized front panel.

8. Starting at bottom, lift and drape

insulation blankets over top of system.

9. Remove front air channel by pulling

out at top.

10. Remove electrical panel cover and

locate element screw kit and outdoor

sensor.

• DO remove the Comfort Plus

system from its shipping pallet

before installing.

• DO NOT extend leveling legs more

than one inch.

• DO use and follow generally ac-

cepted safety practices when

handling insulation material.

• DO have equipment installed by a

qualified technician in compliance

with all applicable local, state and

national codes and regulations.

• Reference Owner’s and Installer’s

Manual for complete safety, instal-

lation, and operation

instructions.

Starting at the back of the brick core, load

bricks one row at a time using left side, right

side, center pattern. Place bricks with grooved

side facing up, notch facing forward, and ridge

on left and right.

• Remove loose brick

debris from brick.

• Brick rows MUST line

up front to back

and side to side.

• Use half bricks in proper rows and in

correct positions. Back half of brick

MUST be installed in back rows. Front

half (notched brick piece) MUST be

installed in front rows.

WARNING

WARNING

WARNING

WARNING

WARNING

with ECM Variable Speed

Blower System

Advertising